UPS Systems
- PCs and Servers to 1.5kVA
- Servers and Networks to 3kVA
- Comms Room UPS to 20kVA
- Datacentres 10-800kVA
- Rackmount 500VA-40kVA
- Modular Systems 25kW-1MW
- Models by Size 500VA-800kVA
- Models by Technology
- Extended Backup Times
- Single Phase 400VA-20kVA
- Three Phase 10-800kVA
- Containerised UPS Systems
- 120Vac US Systems
- Telecoms UPS
- Industrial Plants
- Marine and Offshore Systems
- UPS with an Energy Saving Eco Mode
- UPS with Super Capacitors
- UPS with Lithium-ion Batteries
- UPS with Flywheels
- Power Distribution
- Inverters/Chargers
- Battery Systems
- Voltage Management
- Energy Management
- Power/Energy Monitoring
- Renewable/Off-Grid Power
- Accessories
- Connectivity/Software
-
Eco Power Services
- Battery Testing
- Battery Installations
- Generator Services
- Load Bank Testing
- Project Management
- Removals and Recycling
- Remote Site Monitoring
- Repair and Refurbishment
- Site Surveys
- Technical Helpdesk
- UPS/Generator Rentals
- UPS/Generator Relocations
- UPS Installations
- UPS Maintenance Contracts
- UPS Repairs/Spares
- Warranties and Extensions
- Witness Testing
- Eco Power Projects
UPS Systems with an ECO-mode
Eco Mode UPS can achieve deliver higher operating efficiencies (up to 99%) and energy savings than the On-line (VFS-SS-111) mode typically used for critical datacentre type loads.
When a UPS is set to run in Eco Mode, the operation mimics that of a Line Interactive UPS. In line interactive operation the inverter only powers the load when the mains power supply fluctuates outside preset tolerances. When a stable source of AC power is present (either the mains power supply or a generator), the UPS inverter is powered down and connects the load to an internally filtered and stabilised supply. The power quality of the UPS in terms of protection from mains borne spikes and electrical noise, sags, surges and brownouts will depend on the UPS design: transformerless or transformer-based.
Smart Mode is an alternative operation which can also provide energy savings but provide superior protection to the load than Line Interactive operation. In Smart Mode, the UPS decides whether to operate in On-line or Line Interactive mode based on the state and stability of the AC power supply. Standby Mode is also available with some UPS designs. In Standby mode the inverter reactivation time can be longer than line interactive operation and therefore this mode is recommended only for security systems, emergency lighting and less critical loads.
For high efficiency on-line UPS systems we recommend UPS from the Carbon Trust’s Energy Technology List.
Contact the Eco Power Projects team to book a FREE site survey, discuss our trade-in service or Health Check an existing system for a maintenance plan.
On-line Double Conversion Mode
On-line double-conversion UPS run their inverter section constantly to power the load. The output waveform is digitally generated and the UPS can either be transformerless or transformer-based. This type of UPS is classified as Voltage and Frequency Independent (VFI) under EN 62040-3. This mode of operation is always recommended for critical power loads such as IT, telecoms and datacentres as it provides the best form of power protection, output security and electrical supply. For more information see our guide to the Code of Conduct on the Energy Efficiency and Quality of AC Uninterruptible Power Supplies.