Extended Backup Times
Project Site Surveys
 Power Distribution Units

Extended Long Runtime UPS Systems

Three Phase UPS 8-600kVA

See our Three Phase UPS extended runtime tables page for examples of UPS and battery extension pack configurations from 8 to 600kVA including 3/1 and 3/3  three phase UPS configurations. The table includes UPS  with larger internal batteries and  battery packs some of which have to be built on-site due to their weight and physical size.

Single Phase UPS 700VA-20kVA

The UPS within this collection run to up to 20kVA and can be installed with battery extension packs using plug-in or hardwired terminal connectors to achieve a longer battery autonomy up to 7 hours or more. Jump to the UPS Manufacturer runtime tables on this page: Riello or Eaton or Huawei

Please contact our Power Projects Team if you want a load/runtime configuration not shown in the tables below or require further assistance.

Line Interactive Extended Runtime UPS

Line interactive UPS typically have an internal battery and a matching battery extension pack which connects to a rear panel battery socket. If more than one battery pack is used these are ‘daisy-chained’ together through interconnecting cables and sockets on the rear of the battery extension packs and the number of battery packs may be limited by the UPS battery charging capability. Please check per model if more than one battery extension pack is required as our technical team can advise and size the UPS and battery Ah (Ampere-Hour) required accordingly.

On-line Long Runtime UPS

On-line UPS within this collection may also incorporate a built-in battery pack or in the ‘ER’ models this space is used to house an internal charger for the extended runtime battery packs. To achieve long runtimes the battery extension packs are daisy-chained together but there may be a limit (on a model-by-model basis) as to the number that can be used.

Long Backup UPS Notes

Uninterruptible power supplies with an inverter rated for continuous running can have additional battery extension packs added to their configuration to increase the amount of battery runtime available when the mains power supply fails.

Care has to be taken to ensure that the battery extension packs for the extended backup UPS can be charged within a reasonable recharge period (typically to 80% capacity within 24hours). This is normally achieved by using the existing UPS charging capability or by installing battery extension packs with their own internal chargers; these will also require their own mains power supply connection.

Riello UPS Systems Extended Battery Backup Configurations

Load100% Load50% LoadRangeUPSBEPsBEP SKU
1kVA18m36mSentinel DualSDH10001BBSDH36A3

19m38mSentinel ProSEP10001BBSEP36A3

31m1hSentinel DualSDH10001BBSDH36M1

35m1h10Sentinel ProSEP10001BBSEP36M1

1h62h10

2BBSEP36M1

1h182h35
SEP1000ER1BBSEP36B1

3h36h

2BBSEP36B1

4h559h50

3BBSEP36B1

7h514h10

4BBSEP36B1
2kVA16m31mSentinel ProSEP22001BBSEP72A3

31m1h

1BBSEP72M1

58m1h50

2BBSEP72M1

1h82h10
SEP2200ER1BBSEP72B1

2h444h20

2BBSEP72B1

4h208h40

3BBSEP72B1

6h1812h15

4BBSEP72B1
2.2kVA18m50mVision DualDVD220ER1BBDVD96A5

10m20mSentinel DualSDH22001BBSDH72A3

30m1h 
1BBSDH72M1

1h2m2h SDH2200ER1BBSDH72B1
3kVA11m22mSentinel ProSEP30001BBSEP72A3

13m40mVision DualDVD300ER1BBDVD96A5

13m26mSentinel DualSDH30001BBSDH72A3

20m40mSentinel ProSEP30001BBSEP72M1

22m40mSentinel DualSDH30001BBSDH72M1

40m1h20Sentinel ProSEP30002BBSEP72M1

46m1h25Sentinel ProSEP3000ER1BBSEP72B1

35m1h10Sentinel DualSDH3000ER1BBSDH72B1

1h353h

2BBSDH72B1

1h543h45Sentinel ProSEP3000ER2BBSEP72B1

3h36h5

3BBSEP72B1

4h158h20

4BBSEP72B1
3.3kVA17m33mSentinel DualSDL33001BBSDL108A4

28m55m

1BCSDL108M1

52m1h43

2BCSDL108M1

1h182h35

3BCSDL108M1
4kVA12m23mSentinel DualSDL40001BBSDL108A4

20m39m

1BCSDL108M1

45m1h29

2BCSDL108M1

1h102h19

3BCSDL108M1
5kVA21m41mSentinel Dual
SDL50001BBSDL192A3

30m59m

1BCSDL192A6

54m1h13

2BCSDL192A6
6kVA17m33mSentinel DualSDL60001BBSDL192A3

25m49m

1BCSDL192A6

45m1h29

2BCSDL192A6
8kVA18m35mSentinel DualSDL80001BCSDL240A5

30m59m

2BCSDL240A5
10kVA14m27mSentinel DualSDL100001BCSDL240A5

22m43mSentinel 
2BCSDL240A5

25m48mSentinel Power GreenSPH101BBSPH240-M4

51m50m

2BBSPH240-M4

47m1h32Sentinel Power GreenSPH10ER1BB1600 240-B1

1h122h22

1BB1600 240-B2
15KVA17m32mSentinel Power GreenSPH151BB1320 480-T4

27m52mSentinel Power Green
1BB1320 480-T2

30m58m

1BB1320 480-T5
20KVA14m26mSentinel Power GreenSPH201BB1320 480-T4

20m38m

1BB1320 480-T2

25m48m

1BB1320 480-T5

47m1h32Sentinel Power GreenSPH20ER1BB1600 480-S5

1h122h22

1BB1600 480-V6

Eaton UPS Systems Extended Battery Backup Configurations

Eaton 5130 Series UPS

For more information see the Eaton 5130 UPS range.

Load100% Load50% LoadUPSBEPsBEP SKU
1.25kVA1h1h451250VA11250VA EBM

2h102h55
21250VA EBM

1h3h45
31250VA EBM

3h5h
41250VA EBM
1.75kVA40m1h1750VA11750VA EBM

1h101h20
21750VA EBM

1h302h25
31750VA EBM

1h503h
41750VA EBM
2.5kVA1h1h252500VA12500-3000VA EBM

1h302h20
22500-3000VA EBM

2h203h20
32500-3000VA EBM

3h204h50
42500-3000VA EBM
3kVA45m1h3000VA12500-3000VA EBM

1h201h50
22500-3000VA EBM

1h502h30
32500-3000VA EBM

2h103h20
42500-3000VA EBM

Eaton 9130 Series UPS

For more information see the Eaton 9130 Tower UPS.

Load100% Load50% LoadUPSBEPsBEP SKU
1kVA31m1h8103006434-659111000VA EBM

51m1h50
21000VA EBM

1h223h12
31000VA EBM

1h404h6
41000VA EBM
1.5kVA31m1h8103006435-659111500VA EBM

51m1h50
21500VA EBM

1h223h12
31500VA EBM

1h404h6
41500VA EBM
2kVA31m1h8103006436-659112000VA EBM

51m1h50
22000VA EBM

1h223h12
32000VA EBM

1h404h6
42000VA EBM
3kVA31m1h8103006437-659113000VA EBM

51m1h50
23000VA EBM

1h223h12
33000VA EBM

1h404h6
43000VA EBM
5kVA31m1h8103007841-659115000VA EBM

51m1h50
25000VA EBM

1h223h12
35000VA EBM

1h404h6
45000VA EBM
6kVA31m1h8103007842-659116000VA EBM

51m1h50
26000VA EBM

1h223h12
36000VA EBM

1h404h6
46000VA EBM

Eaton 9130 Series UPS Rackmount

For more information see the Eaton 9130 Rack UPS.

Load100% Load50% LoadUPSBEPsBEP SKU
1kVA31m1h8103006455-659111000VA EBM

51m1h50
21000VA EBM

1h223h12
31000VA EBM

1h404h6
41000VA EBM
1.5kVA31m1h8103006456-659111500VA EBM

51m1h50
21500VA EBM

1h223h12
31500VA EBM

1h404h6
41500VA EBM
2kVA31m1h8103006457-659112000VA EBM

51m1h50
22000VA EBM

1h223h12
32000VA EBM

1h404h6
42000VA EBM
3kVA31m1h8103006463-659113000VA EBM

51m1h50
23000VA EBM

1h223h12
33000VA EBM

1h404h6
43000VA EBM 

Eaton 5PX Series UPS

For more information see the Eaton 5PX UPS range.

Load100% Load50% LoadUPSBEPsBEP SKU
1.5kVA34m1h305PX1500iRT11.5kVA EBM

1h42h35
21.5kVA EBM

1h353h40
31.5kVA EBM

2h54h25
41.5kVA EBM
2.2kVA22m1h5PX2200iRT12.2kVA EBM

40m1h50
22.2kVA EBM

58m2h40
32.2kVA EBM

1h163h20
42.2kVA EBM
3kVA26m1h65PX3000iRT3U13kVA EBM

47m1h55
23kVA EBM

1h92h44
33kVA EBM

1h303h33
43kVA EBM

Eaton 9SX/9PX Series UPS

For more information see the Eaton 9SX/9PX UPS range.

Load100% Load50% LoadUPSBEPsBEP SKU
5kVA20m48m9SX5KiRT15kVA EBM

38m1h28
25kVA EBM

54m2h3
35kVA EBM

1h202h47
45kVA EBM

1h413h20
55kVA EBM

1h554h14
65kVA EBM

2h174h58
75kVA EBM

2h386h13
85kVA EBM

2h557h13
95kVA EBM

3h198h
105kVA EBM

3h428h42
115kVA EBM

4h29h15
125kVA EBM
6kVA16m38m9SX6KiRT16kVA EBM

28m1h11
26kVA EBM

47m1h54
36kVA EBM

58m2h13
46kVA EBM

1h222h50
56kVA EBM

1h403h26
66kVA EBM

1h524h1
76kVA EBM

2h64h41
86kVA EBM

2h275h31
96kVA EBM

2h436h29
106kVA EBM

2h577h17
116kVA EBM

3h177h58
126kVA EBM
8kVA12m29m9SX8Ki18kVA EBM

21m51m
28kVA EBM

29m1h13
38kVA EBM

42m1h35
48kVA EBM

51m1h54
58kVA EBM

1h2h12
68kVA EBM

1h132h34
78kVA EBM

1h282h51
88kVA EBM

1h383h11
98kVA EBM

1h473h37
108kVA EBM

1h533h59
118kVA EBM
11kVA6m18m9SX11Ki111kVA EBM

10m33m
211kVA EBM

18m48m9SX11Ki311kVA EBM

24m1h3
411kVA EBM

33m1h23
511kVA EBM

40m1h40
611kVA EBM

48m1h51
711kVA EBM

56m1h59
811kVA EBM

1h42h18
911kVA EBM

1h152h33
1011kVA EBM

1h232h46
1111kVA EBM

Huawei UPS Systems Extended Backup Configurations

Huawei UPS2000A On-line Tower UPS 1-3kVA UPS

For more information see the Huawei UPS2000A UPS.

Load100% Load50% LoadUPSBEPsBEP SKU
1kVA15m39m1kVA1ESS-36V12-9AHBPVBB

36m1h23
2ESS-36V12-9AHBPVBB
2kVA17m45m2kVA1ESS-72V12-9AHBPVBB

39m1h35m
2ESS-72V12-9AHBPVBB
3kVA17m45m3kVA1ESS-96V12-9AHBPVBB01

39m1h35
2ESS-96V12-9AHBPVBB02

Huawei UPS2000G On-line Tower/Rack Mount UPS 6-10kVA UPS

For more information see the Huawei UPS2000G UPS.

Load100% Load50% LoadUPSBEPsBEP SKU
6kVA6m12m6kVA17AHBPVBA01

19m38m6kVAER17AHBPVBA01

29m58m
17AHBPVBA01

46m1h32
17AHBPVBA01
10kVA4m12m10kVA19AHBPVBA01

12m32m10kVAER19AHBPVBA01

23m53m
19AHBPVBA01

32m1h10
19AHBPVBA01
15kVA19m48m15kVA49AHBPVBA01

32m48m
69AHBPVBA01

48m1h36
89AHBPVBA01
20kVA12m32m20kVA49AHBPVBA01

23m53m
69AHBPVBA01

32m1h10
89AHBPVBA01

Contact the Eco Power Projects team to book a FREE site survey for your extended backup UPS application, discuss our trade-in service or Health Check an existing system for a maintenance plan.

Read-more

Extended Long Runtime UPS Systems

The UPS within this collection run to up to 20kVA and can be installed with battery extension packs using plug-in or hardwired terminal connectors to achieve a longer battery autonomy up to 7 hours or more.

Jump to the UPS Manufacturer runtime tables on this page: Riello or Eaton or Huawei

Please contact our Power Projects Team if you want a load/runtime configuration not shown in the tables below or require further assistance.

Three Phase UPS 10-500kVA

See our Three Phase UPS extended runtime tables for examples of UPS and battery extension pack configurations from 10 to 500kVA three phase. This table includes UPS systems with larger internal batteries and also battery packs some of which have to be built on-site due to their weight and physical size.

Line Interactive Extended Runtime UPS

Line interactive UPS typically have an internal battery and a matching battery extension pack which connects to a rear panel battery socket. If more than one battery pack is used these are ‘daisy-chained’ together through interconnecting cables and sockets on the rear of the battery extension packs and the number of battery packs may be limited by the UPS battery charging capability. Please check per model if more than one battery extension pack is required as our technical team can advise and size the UPS and battery Ah (Ampere-Hour) required accordingly.

On-line Long Runtime UPS

On-line UPS within this collection may also incorporate a built-in battery pack or in the ‘ER’ models this space is used to house an internal charger for the extended runtime battery packs. To achieve long runtimes the battery extension packs are daisy-chained together but there may be a limit (on a model-by-model basis) as to the number that can be used.

Long Backup UPS Notes

Uninterruptible power supplies with an inverter rated for continuous running can have additional battery extension packs added to their configuration to increase the amount of battery runtime available when the mains power supply fails.

Care has to be taken to ensure that the battery extension packs for the extended backup UPS can be charged within a reasonable recharge period (typically to 80% capacity within 24hours). This is normally achieved by using the existing UPS charging capability or by installing battery extension packs with their own internal chargers; these will also require their own mains power supply connection.

Riello UPS Systems Extended Battery Backup Configurations

Load 100% Load 50% Load Range UPS BEPs BEP SKU
1kVA 18m 36m Sentinel Dual SDH1000 1 BBSDH36A3
1kVA 19m 38m Sentinel Pro SEP1000 1 BBSEP36A3
1kVA 31m 1h Sentinel Dual SDH1000 1 BBSDH36M1
1kVA 35m 1h10 Sentinel Pro SEP1000 1 BBSEP36M1
1kVA 1h6 2h10 Sentinel Pro SEP1000 2 BBSEP36M1
1kVA 1h18 2h35 Sentinel Pro SEP1000ER 1 BBSEP36B1
1kVA 3h3 6h Sentinel Pro SEP1000ER 2 BBSEP36B1
1kVA 4h55 9h50 Sentinel Pro SEP1000ER 3 BBSEP36B1
1kVA 7h5 14h10 Sentinel Pro SEP1000ER 4 BBSEP36B1
2kVA 16m 31m Sentinel Pro SEP2200 1 BBSEP72A3
2kVA 31m 1h Sentinel Pro SEP2200 1 BBSEP72M1
2kVA 58m 1h50 Sentinel Pro SEP2200 2 BBSEP72M1
2kVA 1h8 2h10 Sentinel Pro SEP2200ER 1 BBSEP72B1
2kVA 2h44 4h20 Sentinel Pro SEP2200ER 2 BBSEP72B1
2kVA 4h20 8h40 Sentinel Pro SEP2200ER 3 BBSEP72B1
2kVA 6h18 12h15 Sentinel Pro SEP2200ER 4 BBSEP72B1
2.2kVA 18m 50m Vision Dual DVD220ER 1 BBDVD96A5
2.2kVA 10m 20m Sentinel Dual SDH2200 1 BBSDH72A3
2.2kVA 30m 1h Sentinel Dual SDH2200 1 BBSDH72M1
2.2kVA 1h2m 2h Sentinel Dual SDH2200ER 1 BBSDH72B1
3kVA 11m 22m Sentinel Pro SEP3000 1 BBSEP72A3
3kVA 13m 40m Vision Dual DVD300ER 1 BBDVD96A5
3kVA 13m 26m Sentinel Dual SDH3000 1 BBSDH72A3
3kVA 20m 40m Sentinel Pro SEP3000 1 BBSEP72M1
3kVA 22m 40m Sentinel Dual SDH3000 1 BBSDH72M1
3kVA 40m 1h20 Sentinel Pro SEP3000 2 BBSEP72M1
3kVA 46m 1h25 Sentinel Pro SEP3000ER 1 BBSEP72B1
3kVA 35m 1h10 Sentinel Dual SDH3000ER 1 BBSDH72B1
3kVA 1h35 3h Sentinel Dual SDH3000ER 2 BBSDH72B1
3kVA 1h54 3h45 Sentinel Pro SEP3000ER 2 BBSEP72B1
3kVA 3h3 6h5 Sentinel Pro SEP3000ER 3 BBSEP72B1
3kVA 4h15 8h20 Sentinel Pro SEP3000ER 4 BBSEP72B1
3.3kVA 17m 33m Sentinel Dual SDL3300 1 BBSDL108A4
3.3kVA 28m 55m Sentinel Dual SDL3300 1 BCSDL108M1
3.3kVA 52m 1h43 Sentinel Dual SDL3300 2 BCSDL108M1
3.3kVA 1h18 2h35 Sentinel Dual SDL3300 3 BCSDL108M1
4kVA 12m 23m Sentinel Dual SDL4000 1 BBSDL108A4
4kVA 20m 39m Sentinel Dual SDL4000 1 BCSDL108M1
4kVA 45m 1h29 Sentinel Dual SDL4000 2 BCSDL108M1
4kVA 1h10 2h19 Sentinel Dual SDL4000 3 BCSDL108M1
5kVA 21m 41m Sentinel Dual SDL5000 1 BBSDL192A3
5kVA 30m 59m Sentinel Dual SDL5000 1 BCSDL192A6
5kVA 54m 1h13 Sentinel Dual SDL5000 2 BCSDL192A6
6kVA 17m 33m Sentinel Dual SDL6000 1 BBSDL192A3
6kVA 25m 49m Sentinel Dual SDL6000 1 BCSDL192A6
6kVA 45m 1h29 Sentinel Dual SDL6000 2 BCSDL192A6
8kVA 18m 35m Sentinel Dual SDL8000 1 BCSDL240A5
8kVA 30m 59m Sentinel Dual SDL8000 2 BCSDL240A5
10kVA 14m 27m Sentinel Dual SDL10000 1 BCSDL240A5
10kVA 22m 43m Sentinel Dual SDL10000 2 BCSDL240A5
10KVA 25m 48m Sentinel Power Green SPH10 1 BBSPH240-M4
10KVA 51m 50m Sentinel Power Green SPH10 2 BBSPH240-M4
10KVA 47m 1h32 Sentinel Power Green SPH10ER 1 BB1600 240-B1
10KVA 1h12 2h22 Sentinel Power Green SPH10ER 1 BB1600 240-B2
15KVA 17m 32m Sentinel Power Green SPH15 1 BB1320 480-T4
15KVA 27m 52m Sentinel Power Green SPH15 1 BB1320 480-T2
15KVA 30m 58m Sentinel Power Green SPH15 1 BB1320 480-T5
20KVA 14m 26m Sentinel Power Green SPH20 1 BB1320 480-T4
20KVA 20m 38m Sentinel Power Green SPH20 1 BB1320 480-T2
20KVA 25m 48m Sentinel Power Green SPH20 1 BB1320 480-T5
20KVA 47m 1h32 Sentinel Power Green SPH20ER 1 BB1600 480-S5
20KVA 1h12 2h22 Sentinel Power Green SPH20ER 1 BB1600 480-V6

Eaton UPS Systems Extended Battery Backup Configurations


Eaton 5130 Series UPS

Load 100% Load 50% Load Range UPS BEPs BEP SKU
1.25kVA 1h 1h45 Eaton 5130 1250VA 1 1250VA EBM
1.25kVA 2h10 2h55 Eaton 5130 1250VA 2 1250VA EBM
1.25kVA 1h 3h45 Eaton 5130 1250VA 3 1250VA EBM
1.25kVA 3h 5h Eaton 5130 1250VA 4 1250VA EBM
1.75kVA 40m 1h Eaton 5130 1250VA 1 1750VA EBM
1.75kVA 1h10 1h20 Eaton 5130 1250VA 2 1750VA EBM
1.75kVA 1h30 2h25 Eaton 5130 1250VA 3 1750VA EBM
1.75kVA 1h50 3h Eaton 5130 1250VA 4 1750VA EBM
2.5kVA 1h 1h25 Eaton 5130 1250VA 1 2500-3000VA EBM
2.5kVA 1h30 2h20 Eaton 5130 1250VA 2 2500-3000VA EBM
2.5kVA 2h20 3h20 Eaton 5130 1250VA 3 2500-3000VA EBM
2.5kVA 3h20 4h50 Eaton 5130 1250VA 4 2500-3000VA EBM
3kVA 45m 1h Eaton 5130 1250VA 1 2500-3000VA EBM
3kVA 1h20 1h50 Eaton 5130 1250VA 2 2500-3000VA EBM
3kkVA 1h50 2h30 Eaton 5130 1250VA 3 2500-3000VA EBM
3kVA 2h10 3h20 Eaton 5130 1250VA 4 2500-3000VA EBM

Eaton 9130 Series UPS


Eaton 9130 Series UPS Rackmount


Eaton 5PX Series UPS

Load 100% Load 50% Load Range UPS BEPs BEP SKU
1.5kVA 34m 1h30 Eaton 5PX 5PX1500iRT 1 1.5kVA EBM
1.5kVA 1h4 2h35 Eaton 5PX 5PX1500iRT 2 1.5kVA EBM
1.5kVA 1h35 3h40 Eaton 5PX 5PX1500iRT 3 1.5kVA EBM
1.5kVA 2h5 4h25 Eaton 5PX 5PX1500iRT 4 1.5kVA EBM
2.2kVA 22m 1h Eaton 5PX 5PX2200iRT 1 2.2kVA EBM
2.2kVA 40m 1h50 Eaton 5PX 5PX2200iRT 2 2.2kVA EBM
2.2kVA 58m 2h40 Eaton 5PX 5PX2200iRT 3 2.2kVA EBM
2.2kVA 1h16 3h20 Eaton 5PX 5PX2200iRT 4 2.2kVA EBM
3kVA 26m 1h6 Eaton 5PX 5PX3000iRT3U 1 3kVA EBM
3kVA 47m 1h55 Eaton 5PX 5PX3000iRT3U 2 3kVA EBM
3kVA 1h9 2h44 Eaton 5PX 5PX3000iRT3U 3 3kVA EBM
3kVA 1h30 3h33 Eaton 5PX 5PX3000iRT3U 4 3kVA EBM


Eaton 9SX Series UPS

Load 100% Load 50% Load Range UPS BEPs BEP SKU
5kVA 20m 48m Eaton 9SX 9SX5KiRT 1 5kVA EBM
5kVA 38m 1h28 Eaton 9SX 9SX5KiRT 2 5kVA EBM
5kVA 54m 2h3 Eaton 9SX 9SX5KiRT 3 5kVA EBM
5kVA 1h20 2h47 Eaton 9SX 9SX5KiRT 4 5kVA EBM
5kVA 1h41 3h20 Eaton 9SX 9SX5KiRT 5 5kVA EBM
5kVA 1h55 4h14 Eaton 9SX 9SX5KiRT 6 5kVA EBM
5kVA 2h17 4h58 Eaton 9SX 9SX5KiRT 7 5kVA EBM
5kVA 2h38 6h13 Eaton 9SX 9SX5KiRT 8 5kVA EBM
5kVA 2h55 7h13 Eaton 9SX 9SX5KiRT 9 5kVA EBM
5kVA 3h19 8h Eaton 9SX 9SX5KiRT 10 5kVA EBM
5kVA 3h42 8h42 Eaton 9SX 9SX5KiRT 11 5kVA EBM
5kVA 4h2 9h15 Eaton 9SX 9SX5KiRT 12 5kVA EBM
6kVA 16m 38m Eaton 9SX 9SX6KiRT 1 6kVA EBM
6kVA 28m 1h11 Eaton 9SX 9SX6KiRT 2 6kVA EBM
6kVA 47m 1h54 Eaton 9SX 9SX6KiRT 3 6kVA EBM
6kVA 58m 2h13 Eaton 9SX 9SX6KiRT 4 6kVA EBM
6kVA 1h22 2h50 Eaton 9SX 9SX6KiRT 5 6kVA EBM
6kVA 1h40 3h26 Eaton 9SX 9SX6KiRT 6 6kVA EBM
6kVA 1h52 4h1 Eaton 9SX 9SX6KiRT 7 6kVA EBM
6kVA 2h6 4h41 Eaton 9SX 9SX6KiRT 8 6kVA EBM
6kVA 2h27 5h31 Eaton 9SX 9SX6KiRT 9 6kVA EBM
6kVA 2h43 6h29 Eaton 9SX 9SX6KiRT 10 6kVA EBM
6kVA 2h57 7h17 Eaton 9SX 9SX6KiRT 11 6kVA EBM
6kVA 3h17 7h58 Eaton 9SX 9SX6KiRT 12 6kVA EBM
8kVA 12m 29m Eaton 9SX 9SX8Ki 1 8kVA EBM
8kVA 21m 51m Eaton 9SX 9SX8Ki 2 8kVA EBM
8kVA 29m 1h13 Eaton 9SX 9SX8Ki 3 8kVA EBM
8kVA 42m 1h35 Eaton 9SX 9SX8Ki 4 8kVA EBM
8kVA 51m 1h54 Eaton 9SX 9SX8Ki 5 8kVA EBM
8kVA 1h 2h12 Eaton 9SX 9SX8Ki 6 8kVA EBM
8kVA 1h13 2h34 Eaton 9SX 9SX8Ki 7 8kVA EBM
8kVA 1h28 2h51 Eaton 9SX 9SX8Ki 8 8kVA EBM
8kVA 1h38 3h11 Eaton 9SX 9SX8Ki 9 8kVA EBM
8kVA 1h47 3h37 Eaton 9SX 9SX8Ki 10 8kVA EBM
8kVA 1h53 3h59 Eaton 9SX 9SX8Ki 11 8kVA EBM
11kVA 6m 18m Eaton 9SX 9SX11Ki 1 11kVA EBM
11kVA 10m 33m Eaton 9SX 9SX11Ki 2 11kVA EBM
11kVA 18m 48m Eaton 9SX 9SX11Ki 3 11kVA EBM
11kVA 24m 1h3 Eaton 9SX 9SX11Ki 4 11kVA EBM
11kVA 33m 1h23 Eaton 9SX 9SX11Ki 5 11kVA EBM
11kVA 40m 1h40 Eaton 9SX 9SX11Ki 6 11kVA EBM
11kVA 48m 1h51 Eaton 9SX 9SX11Ki 7 11kVA EBM
11kVA 56m 1h59 Eaton 9SX 9SX11Ki 8 11kVA EBM
11kVA 1h4 2h18 Eaton 9SX 9SX11Ki 9 11kVA EBM
11kVA 1h15 2h33 Eaton 9SX 9SX11Ki 10 11kVA EBM
11kVA 1h23 2h46 Eaton 9SX 9SX11Ki 11 11kVA EBM

Huawei UPS Systems Extended Backup Configurations

Huawei UPS2000A On-line Tower UPS 1-3kVA UPS

Load 100% Load 50% Load Range UPS BEPs BEP SKU
1kVA 15m 39m Huawei UPS2000A 1kVA 1 ESS-36V12-9AHBPVBB
1kVA 36m 1h23 Huawei UPS2000A 1kVA 2 ESS-36V12-9AHBPVBB
2kVA 17m 45m Huawei UPS2000A 2kVA 1 ESS-72V12-9AHBPVBB
2kVA 39m 1h35m Huawei UPS2000A 2kVA 2 ESS-72V12-9AHBPVBB
3kVA 17m 45m Huawei UPS2000A 3kVA 1 ESS-96V12-9AHBPVBB01
3kVA 39m 1h35 Huawei UPS2000A 3kVA 2 ESS-96V12-9AHBPVBB02


Huawei UPS2000G On-line Tower/Rack Mount UPS 6-10kVA UPS

Load 100% Load 50% Load Range UPS BEPs BEP SKU
6kVA 6m 12m Huawei UPS2000G 6kVA 1 7AHBPVBA01
6kVA 19m 38m Huawei UPS2000G 6kVAER 1 7AHBPVBA01
6kVA 29m 58m Huawei UPS2000G 6kVAER 1 7AHBPVBA01
6kVA 46m 1h32 Huawei UPS2000G 6kVAER 1 7AHBPVBA01
10kVA 4m 12m Huawei UPS2000G 10kVA 1 9AHBPVBA01
10kVA 12m 32m Huawei UPS2000G 10kVAER 1 9AHBPVBA01
10kVA 23m 53m Huawei UPS2000G 10kVAER 1 9AHBPVBA01
10kVA 32m 1h10 Huawei UPS2000G 10kVAER 1 9AHBPVBA01
15kVA 19m 48m Huawei UPS2000G 15kVA 4 9AHBPVBA01
15kVA 32m 48m Huawei UPS2000G 15kVA 6 9AHBPVBA01
15kVA 48m 1h36 Huawei UPS2000G 15kVA 8 9AHBPVBA01
20kVA 12m 32m Huawei UPS2000G 20kVA 4 9AHBPVBA01
20kVA 23m 53m Huawei UPS2000G 20kVA 6 9AHBPVBA01
20kVA 32m 1h10 Huawei UPS2000G 20kVA 8 9AHBPVBA01

Contact the Eco Power Projects team to book a FREE site survey for your extended backup UPS application, discuss our trade-in service or Health Check an existing system for a maintenance plan.