UPS Systems
- PCs and Servers to 1.5kVA
- Servers and Networks to 3kVA
- Comms Room UPS to 20kVA
- Datacentres 10-800kVA
- Rackmount 500VA-40kVA
- Modular Systems 25kW-1MW
- Models by Size 500VA-800kVA
- Models by Technology
- Extended Backup Times
- Single Phase 400VA-20kVA
- Three Phase 10-800kVA
- Containerised UPS Systems
- 120Vac US Systems
- Telecoms UPS
- Industrial Plants
- Marine and Offshore Systems
- UPS with an Energy Saving Eco Mode
- UPS with Super Capacitors
- UPS with Lithium-ion Batteries
- UPS with Flywheels
- Power Distribution
- Inverters/Chargers
- Battery Systems
- Voltage Management
- Energy Management
- Power/Energy Monitoring
- Renewable/Off-Grid Power
- Accessories
- Connectivity/Software
-
Eco Power Services
- Battery Testing
- Battery Installations
- Generator Services
- Load Bank Testing
- Project Management
- Removals and Recycling
- Remote Site Monitoring
- Repair and Refurbishment
- Site Surveys
- Technical Helpdesk
- UPS/Generator Rentals
- UPS/Generator Relocations
- UPS Installations
- UPS Maintenance Contracts
- UPS Repairs/Spares
- Warranties and Extensions
- Witness Testing
- Eco Power Projects
Replacement UPS Batteries
EcoPowerSupplies provides a range of batteries and associated services:
- Individual Batteries for purchase – listed below – see selection table below images for sizes
- Battery replacement kits for leading UPS brands
- Battery disposal services – including the supply and installation of replacement UPS batteries
- Battery Transition and Junction Boxes
A Yusasa v Fiamm battery comparison table is shown at the bottom of this page.

Replacement UPS Batteries
EcoPowerSupplies provides a range of batteries and associated services:
- Individual Batteries for purchase – listed below – see selection table below images for sizes
- Battery replacement kits for leading UPS brands
- Battery disposal services – including the supply and installation of replacement UPS batteries
- Battery Transition and Junction Boxes
A Yusasa v Fiamm battery comparison table is shown at the bottom of this page.
Battery Ranges
Below we provide a quick overview on the batteries makes and types in this section. We can source a wide range of batteries. Please contact us if you cannot find the battery you need for your standby power application.
- CSB Batteries: use VRLA lead acid technology and are suitable for security and fire panels, emergency lighting and uninterruptible power supplies.
- GNP Sprinter series from Exide Technologies: VRLA lead acid batteries 10 year design life AGM batteries for UPS systems and DC standby power supplies.
- Fiamm FLB, FGH and FGHL Batteries: use VRLA lead acid technology and for uninterruptible power supplies and DC standby power and backup systems.
- Yuasa NP, NPL and Yucel series: VRLA lead lead batteries use oxygen recombination technology and are suitable for security and fire panels, emergency lighting and uninterruptible power supplies.
- Yuasa SWL series: are VRLA lead acid batteries and an enhanced NP/NPL battery giving up to 40% more discharge capacity. They are ideal for high rate discharge applications including UPS systems and have a 10 year design life.
- Yuasa EN Endurance series: VRLA lead acid batteries suitable for standby applications telecommunications, UPS and Emergency Lightning with a long design life (EN series: 10 years, ENL: 15 years)
If you are replacing a battery string we may be able to offer an extended warranty at no extra charge if you also install one of our battery monitoring solutions.
For more information on our replacement UPS batteries please click on any of the products shown below or call the Eco Power Projects team on 0800 612 7388, complete our enquiry form or simply email us. Alternatively click on our replacement UPS batteries guide to see which batteries we recommend on a model by model basis.
Battery Sizing
Batteries are sized based on their Ah (Ampere-Hour) and Vdc (voltage direct current). For the batteries on this page a 7-12 battery would have an Ah rating of 7Ah and a DC voltage of 12Vdc.
Often batteries are connected in series in strings to make a total Vdc battery string:
12Vdc+12Vdc+12Vdc=36Vdc
This 36Vdc battery string could support an inverter with a 36Vdc input requirement. The Ah of the battery defines how long the inverter could run for at a given load.
Using 7Ah in a 36Vdc battery string, a 36Vdc inverter may run for 6 minutes at 100% load or 8 minutes at 80% load (example figures).
If a longer runtime were required then two 36Vdc strings could be connected in parallel. The Vdc would still be 36Vdc but the battery set size would be 2×7=14Ah.
Please let us know if you require any assistance in sizing your batteries.
Yuasa and Fiamm Batteries Comparison Table
Yusa Battery | Ah | L | W | H | Kg | Fiamm Battery | Ah | L | W | H | Kg |
---|---|---|---|---|---|---|---|---|---|---|---|
SWL750 | 25 | 166 | 175 | 125 | 9 | 12FLB100 | 26 | 166 | 175 | 126 | 9.35 |
SWL1100 | 40 | 197 | 165 | 170 | 14 | 12FLB150 | 40 | 197 | 165 | 170 | 14 |
SWL1800 | 55 | 216 | 168 | 223 | 23 | 12FLB200 | 55 | 229 | 138 | 212 | 18.5 |
SWL1850 | 66 | 350 | 166 | 174 | 23 | 12FLB250 | 70 | 272 | 166 | 195 | 23.6 |
SWL2250 | 76 | 380 | 166 | 174 | 27.5 | 12FLB300 | 75 | 261 | 174 | 219 | 27 |
SWL2500 | 95 | 305 | 173 | 223 | 36 | 12FLB350 | 95 | 302 | 174 | 219 | 31 |
SWL3300 | 105 | 350 | 168 | 225 | 38 | 12FLB400 | 105 | 341 | 174 | 219 | 34.5 |
SWL3800FR | 135 | 350 | 173 | 272 | 48 | 12FLB450 | 120 | 379 | 174 | 219 | 38.5 |
SWL4250FR | 150 | 341 | 173 | 281 | 49 | 12FLB540 | 150 | 338 | 174 | 278 | 44.5 |
The comparisons are based on V0 (flame retardant) plastic.